Elevator Control

By connecting the AXIS A9188 relay module to a 2N intercom or to a 2N access unit, access to the elevator floors in the building can be controlled. Up to 8 of these relay modules can be connected to one 2N intercom or 2N access unit, each of which being able to control 8 floors, which makes a total of 64 floors. To use this function, you must have an active license: for IP intercoms (Part No. 9137916) or for access units (Part No. 9160401).

Elevator Connection
  1. Connect the inputs of the elevator controllers to the AXIS A9188 relay and connect the relay to the IP network. Make a note of the relay IP address.

    Follow the documentation for the AXIS A9188 I/O Relay Module, available at http://www.axis.com.

  2. Open the web configuration interface of the 2N device that is to manage the elevator accesses.

  3. Go to Integration > Access Control > Elevator.

  4. Enable one of the modules on the Relay Modules (AXIS A9188) tab.

  5. Click the pencil icon Diagonal pencil tilted to the right, Access Commander edit icon and enter the IP address of the relay module into the box that opens.

  6. If the relay access is subject to authentication, enter the username and password on the General tab.

  7. Once the relay module is enabled, the floors managed by this module will appear on the Elevator Floors tab. You can name each floor.

Setting Public Access to Floors:
  1. Select the floors to be accessible to the public (access is not subject to authorization) on the Elevator Floors tab.

  2. Click the pencil icon Diagonal pencil tilted to the right, Access Commander edit icon next to the selected floor.

  3. Enable Public Access in the open settings.

  4. Optionally, select a time profile or set a custom access time to limit the public access time.

Was this page helpful?