Mechanical Installation

Installation Conditions

Make sure that the following 2N IP Force installation conditions are met.

  • There must be enough space for the device installation.

  • Make sure that the dowel holes have the required diameter. If the diameters are too large, the dowels may get loose! Use the mounting glue to secure the dowels if necessary.

  • Do not use low-quality dowels to avoid their falling out of the wall!

  • Make sure that the depths of the dowel holes are accurate! The plugs are 50 mm long and the screws are 90 mm long.

  • Stainless steel screws are used for the 2N IP Force assembly. Other screws than stainless steel ones corrode soon and may aesthetically deteriorate the surrounding environment!

  • Before starting the mechanical installation on a selected place, make sure carefully that the preparations associated with it (drilling, wall cutting) cannot damage the electrical, gas, water and other existing wires and pipes.

  • The device is not designed for environments with increased vibrations such as means of transport, machine rooms and so on.

  • The device may not be exposed to aggressive gas, acid vapors, solvents, etc.

  • The device is not intended for direct connection into the Internet/WAN. The device must be connected to the Internet/WAN via a separating active network element (switch/router).

  • Having removed the front panel, make sure that no dirt gets inside the product, especially onto the sealing surface and microphone wave guides.

    Note

    The microphone sound guides are normally loose after the front panel is removed! The screw is only used as a fall-out protection during installation.

  • Avoid strong electromagnetic radiation on the installation site.

  • Make sure that the VoIP connection is configured properly according to the SIP and other VoIP recommendations.

Warning

Be sure to keep strictly the hole dimensions while mounting the device into classic bricks without the flush mounting box as shown in the picture with dimensions.

Caution

  • When the proper installation instructions are not met, water might get in and destroy the electronics. As the device circuits are constantly under voltage water leakage causes electrochemical reaction. The manufacturer‘s warranty shall be void for products damaged in this way!

  • The warranty does not apply to the product defects and failures arisen as a result of improper installation (in contradiction herewith). The manufacturer is neither liable for damage caused by theft within an area that is accessible after the attached electric lock is switched on. The product is not designed as a burglar protection device except when used in combination with a standard lock, which has the security function.

  • Exceeding the allowed operating temperature may not affect the device immediately but leads to premature ageing and lower reliability. For the acceptable range of operating temperatures and relative humidity values refer to S.Technical Parameters.Technical Parameters

  • Any intentional mechanical damage to the device (drilling, main unit tampering, etc.) results in a loss of warranty.

  • The device installation and setting should only be performed by professionally qualified persons.

Installation Tips

  • The recommended height is 135 cm for standard installations (100–120 cm for disabled persons) from the floor to the device camera level. The installation heights may vary depending on the device use.

  • The mounting box can be purchased in advance. Thus, a building company can be commissioned to do the rough work. The mounting box also helps you put your device exactly in the vertical position (with a max deviation of 2 ° while walling in).