Evacuation Mode

In the Evacuation mode, 2N Lift8 (L8) ensures a reliable communication with the evacuation elevator floors, which is crucial for a safe and rapid evacuation of persons in emergency.

The system is controlled by the Central Unit (CU), which provides telecommunication connection of the audio units with an IP phone. Thus, a responsible and duly trained person can communicate with the evacuees on all the floors via an IP phone, ensuring a successful evacuation process.

The floor audio units are connected to a bus (pair of wires) and to the CU via a splitter. The CU is equipped with an internal splitter of its own. Up to 7 additional splitters can be connected to the CU. Up to 8 audio units can be connected to each splitter. Thus, the 2N Lift8 system can serve up to 64 audio units/floors.

The audio units are numbered 01 to 64. 8 positions are allocated for each splitter, see the table below:

Splitter address

Audio unit numbers

Splitter 1 (CU internal splitter)

01 to 08

Splitter 2

09 to 16

Splitter 3

17 to 24

Splitter 4

25 to 32

Splitter 5

33 to 40

Splitter 6

41 to 48

Splitter 7

49 to 56

Splitter 8

57 to 64

Mode Activation

To switch Lift8 into the Evacuation mode, set parameter 996 to 1 (enabled). Setting parameters is described in Subs. System Configuration.

System diagram

Evac-Mode-Schematic-Lift8.jpg

Main bus

6-wire Main Bus Connection

Bus (audio units)

Dual bus connection schema