2N Lift1 - Configuration backup - How to backup configuration, how to capture it and trace it

Info

This FAQ describe, how to save configuration from communicator unit 2N Lift1 with software 2N Lift1 Service Tool.

  • For configuration download is necessary 2N Programming Tool, for PC connection using USB.

  • Is necessary to have installed 2N Service Tool, actual version can be downloaded on www.2n.com

 

 

PC connection with programming tool:

Info

  • Being programmed, 2N Lift1 is powered from the USB port and need not be connected to a telephone line. Having been disconnected, however, 2N Lift1 loses power and thus all unsaved data.

  • To make your 2N Lift1 remember time, leave the line connected during programming. Thus, no data will be lost after USB disconnection and the line will be detected as seized during programming.

  • The programming interface provides galvanic isolation of the PC and 2N Lift1.

  • The 10-wire interconnecting cable has no key on the 2N Lift1 side, so respect the cable colours (see the figure). An inverse connection does not damage the device.

  • Correct PC and 2N Lift1 connections are indicated by the blue LED on the edge, which goes on and signals power supply.

  • If the PC-2N Lift1 interconnecting program is running in 2N Lift1, the green LED starts shining. If not, mount the proper jumper (refer to 2.5 or 2.7 – Installation universal design / compact version) to switch 2N Lift1 into the recovery mode.

  • The green LED flashes to indicate programming.

 

Lift1_Configuration_backup_1 

Configuration download with service tool

When the 2N Lift1 Programming Tool is connected to a PC, the device is detected and the proper driver is installed. The 2N Lift1 Programming Tool is then automatically assigned a COM port. View the COM port in the Connect to device menu in the 2N Lift1 Service Tool. After connection and configuration download click on "Save to a File".

Lift1_Configuration_backup_2