images/download/thumbnails/104860780/image2023-5-22_12-5-1.png

1. NO LIGHT – POWER OFF – indicates that the 12V power supply of the GPRS
module is disconnected or works erroneously or the fuse is defective.

2. THREE QUICK FLASHES – START or RESTART – indicates the system starts or
restarts. This status must occur whenever the power supply is connected.

3. SLOW FLASHING – INITIALIZATION – indicates the process of module login
to the provider and IP network.

4. VERY QUICK FLASHING – ERROR – indicates an error due to a wrong PIN,
missing SIM card or fewer than three remaining PIN entering attempts.

5. CONSTANT SHINING – OK – 2N®SmartCOM logged in, IP address assigned,
connection was successfully established. A quick flash indicates data transmission in
this status.

 

 

 

LED Signalization

Mode - Primary channel

NO LIGHT

THREE QUICK FLASHES

SLOW FLASHING

ILLUMINATED

QUICK FLASHING

Standalone - GSM

No power supply

Start or restart

Indicates that the module is being connected to the provider / unit lost connectivity to network

Unit is connected to GSM network

Data transmission in progress / Error state - wrong pin / No SIM / PIN entering attempts is lower than three

TCPclient - GSM

No power supply

Start or restart

indicates that the module is being connected to the provider / unit is not connected to the 2N SmartCom Server / unit lost connectivity to network

Unit is connected 2N SmartCom Server

Data transmission in progress / Error state - wrong pin / No SIM / PIN entering attempts is lower than three

Standalone - ETH

No power supply

Start or restart

indicates that the module is being connected to the provider

Unit is connected to network - IP assigned

Data transmission in progress

TCPclient - ETH

No power supply

Start or restart

indicates that the ETH receiving IP connectivity / unit is not connected to the 2N SmartCom Server

Unit is connected 2N SmartCom Server

Data transmission in progress

 