Aplikacje i oprogramowanie
| Nazwa pliku | Kategoria | Typ | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Software 3.6.1 - 2N Access Commander (VirtualBox, VMware) | Oprogramowanie i oprogramowanie sprzętowe | Oprogramowanie | |||||||
2N Access Commander version 3.6.1 (May 2026)2N Access Commander version 3.6 introduces a faster way to configure devices through device templates, a centralised call log for intercoms, a dedicated Company Admin role for managing organisation-level settings, and several quality-of-life improvements throughout the system. Bugs fixed in 3.6.1:Addresses a critical bug that a ects a small number of Access Commander Box installations and My2N app pairing. New Features:Device TemplatesAdmins can now save and edit the configuration file of any 2N OS–based device and apply it to other devices individually or in bulk.
Important:
Call logsCall logs provide administrators with a single, unified view of incoming and outgoing calls from all intercoms and elevator communication devices.
Please note: If both the caller and receiver are managed by Access Commander, the system Company admin roleThe new Company Admin role gives designated users control over company-specific settings that previously required full administrator rights. This role can be combined with others such as User Manager or Visitor Manager, depending on requirements. Company Admin rights include:
Other improvements:Pairing with the My2N mobile app is now faster and more secure. Users can pair the app via a QR code displayed in Access Commander or from a link or QR code sent by email. (Supported on devices running FW 2.50/3.0 and higher).
Required Device Firmware Versions for Full Feature Support
Note - some older 2N devices cannot support versions higher than 2.50. Minimum Supported Firmware Versions (Devices running firmware older than these versions will not sync with Access Commander)
|
|||||||||
| Software 3.6.1 - 2N Access Commander (Hyper-V) | Oprogramowanie i oprogramowanie sprzętowe | Oprogramowanie | |||||||
2N Access Commander version 3.6.1 (May 2026)2N Access Commander version 3.6 introduces a faster way to configure devices through device templates, a centralised call log for intercoms, a dedicated Company Admin role for managing organisation-level settings, and several quality-of-life improvements throughout the system. Bugs fixed in 3.6.1:Addresses a critical bug that a ects a small number of Access Commander Box installations and My2N app pairing. New Features:Device TemplatesAdmins can now save and edit the configuration file of any 2N OS–based device and apply it to other devices individually or in bulk.
Important:
Call logsCall logs provide administrators with a single, unified view of incoming and outgoing calls from all intercoms and elevator communication devices.
Please note: If both the caller and receiver are managed by Access Commander, the system Company admin roleThe new Company Admin role gives designated users control over company-specific settings that previously required full administrator rights. This role can be combined with others such as User Manager or Visitor Manager, depending on requirements. Company Admin rights include:
Other improvements:Pairing with the My2N mobile app is now faster and more secure. Users can pair the app via a QR code displayed in Access Commander or from a link or QR code sent by email. (Supported on devices running FW 2.50/3.0 and higher).
Required Device Firmware Versions for Full Feature Support
Note - some older 2N devices cannot support versions higher than 2.50. Minimum Supported Firmware Versions (Devices running firmware older than these versions will not sync with Access Commander)
|
|||||||||
| Software 3.5.2 - 2N Access Commander (VirtualBox, VMware) | Oprogramowanie i oprogramowanie sprzętowe | Oprogramowanie | |||||||
2N Access Commander version 3.5.2 (February 2026)2N Access Commander version 3.5 introduces enhanced support for 2N Fortis Locks, a new card search function, company specific time profiles, support for emergency elevator communicators and other improvements.
New Features in 3.5.0Enhanced support for 2N Fortis electronic locks
New search improvements
Company specific time profilesIn multi-company installations, admins can now assign new time profiles to companies. An access manager will only see system-wide time profiles or time profiles assigned to their company. The creation of a new time profile by an access manager will not be visible to other companies.2N Emergency Elevator Communicator supportAccess Commander now supports 2N OS based elevator devices (LiftIP 2.0 and Sentrio). The online state of these devices can be monitored from the device list, monitoring page and can be notified by email. As with all 2N OS devices, access to the device web configuration is also supported, with Access Commander remembering the device password.Other improvements:
Required Device Firmware Versions for Full Feature Support
Note - some older 2N devices cannot support versions higher than 2.50.x Minimum Supported Firmware Versions (Devices running firmware older than these versions will not sync with Access Commander)
API Changes
|
|||||||||
| Software 3.5.2 - 2N Access Commander (Hyper-V) | Oprogramowanie i oprogramowanie sprzętowe | Oprogramowanie | |||||||
2N Access Commander version 3.5.2 (February 2026)2N Access Commander version 3.5 introduces enhanced support for 2N Fortis Locks, a new card search function, company specific time profiles, support for emergency elevator communicators and other improvements.
New Features in 3.5.0Enhanced support for 2N Fortis electronic locks
New search improvements
Company specific time profilesIn multi-company installations, admins can now assign new time profiles to companies. An access manager will only see system-wide time profiles or time profiles assigned to their company. The creation of a new time profile by an access manager will not be visible to other companies.2N Emergency Elevator Communicator supportAccess Commander now supports 2N OS based elevator devices (LiftIP 2.0 and Sentrio). The online state of these devices can be monitored from the device list, monitoring page and can be notified by email. As with all 2N OS devices, access to the device web configuration is also supported, with Access Commander remembering the device password.Other improvements:
Required Device Firmware Versions for Full Feature Support
Note - some older 2N devices cannot support versions higher than 2.50.x Minimum Supported Firmware Versions (Devices running firmware older than these versions will not sync with Access Commander)
API Changes
|
|||||||||
| Fortis Commander | Oprogramowanie i oprogramowanie sprzętowe | Oprogramowanie | |||||||
|
|||||||||
| Software 3.4.2 - 2N Access Commander (VirtualBox, VMware) | Oprogramowanie i oprogramowanie sprzętowe | Oprogramowanie | |||||||
2N® Access Commander version 3.4.2 (September 2025)2N® Access Commander version 3.4 introduced a range of new features, detailed below. This subsequent 3.4.2 release adds support for 2N OS firmware 2.49, delivers minor text improvements, and resolves a few small issues.This release includes security fixes and addresses concerns regarding the following user reported vulnerabilities.
It is strongly recommended that all users upgrade to version 3.4.2 to ensure the security of their installation. As with all Access Commander upgrades, this release updates external dependencies critical for security. IMPORTANT - Due to a redesign of the proxy server settings, upgrading to this version from 3.3.1 or lower will erase any existing configuration—administrators will need to re-enter the proxy details after the update. New Features & Improvements:2N Fortis electronic locksThis release supports 2N Fortis wireless electronic locks (handles and cylinders) in offline mode. Locks can be added to Access Commander and assigned to zones, similar to other access readers in the software. 2N Fortis locks adhere to the OSS Secure ID standard, where access rights are stored and encrypted on the card or fob (DESFire EV3) rather than the device itself. Due to the offline nature of these devices, active monitoring or control is not supported. In this version of Access Commander, a 2N intercom or 2N Access Unit is required for writing access rights to cards and must be part of the installation.Proxy exceptions2N Access Commander now supports more granular proxy configuration, allowing administrators to define proxy server exceptions (domains or addresses). This improvement simplifies network management in complex environments, ensuring external services can connect via network proxy while local devices can remain unaffected. This update addresses key customer requests and lays the foundation for future cloud-based functionality.Extended visitor durationUntil now visitors in Access Commander were limited to a maximum visit of 30 days. From Access Commander 3.4 we are increasing this duration to a maximum of 90 days allowing temporary access that can span months. Ideal for customers integrating Access Commander with third-party systems that need support for longer visits.Device typesWe've added a new column to the device list page called 'Types'. It's now even easier to see which device is an intercom, Access Unit, answering unit or electronic lock. The list can be filtered based on the selected type.New DevicesThis release supports the new 2N IP Force 2.0 intercom the 2N Clip 2wire-IP answering unit, and of course, 2N Fortis electronic locks.Additional NotesIMPORTANT - For security reasons, this version of Access Commander is not compatible with 2N Intercoms and 2N Access Units running firmware version 2.37 or older. Access Commander will not manage devices with these firmware versions even if compatibility mode is enabled. Please ensure all devices are running firmware version 2.38 or newer before upgrading.Required Device Firmware Versions for Full Feature Support
Minimum Supported Firmware Versions (Devices running firmware older than these versions will not sync with Access Commander)
API Changes
|
|||||||||
| Software 3.4.2 - 2N Access Commander (Hyper-V) | Oprogramowanie i oprogramowanie sprzętowe | Oprogramowanie | |||||||
2N® Access Commander version 3.4.2 (September 2025)2N® Access Commander version 3.4 introduced a range of new features, detailed below. This subsequent 3.4.2 release adds support for 2N OS firmware 2.49, delivers minor text improvements, and resolves a few small issues.This release includes security fixes and addresses concerns regarding the following user reported vulnerabilities.
It is strongly recommended that all users upgrade to version 3.4.2 to ensure the security of their installation. As with all Access Commander upgrades, this release updates external dependencies critical for security. IMPORTANT - Due to a redesign of the proxy server settings, upgrading to this version from 3.3.1 or lower will erase any existing configuration—administrators will need to re-enter the proxy details after the update. New Features & Improvements:2N Fortis electronic locksThis release supports 2N Fortis wireless electronic locks (handles and cylinders) in offline mode. Locks can be added to Access Commander and assigned to zones, similar to other access readers in the software. 2N Fortis locks adhere to the OSS Secure ID standard, where access rights are stored and encrypted on the card or fob (DESFire EV3) rather than the device itself. Due to the offline nature of these devices, active monitoring or control is not supported. In this version of Access Commander, a 2N intercom or 2N Access Unit is required for writing access rights to cards and must be part of the installation.Proxy exceptions2N Access Commander now supports more granular proxy configuration, allowing administrators to define proxy server exceptions (domains or addresses). This improvement simplifies network management in complex environments, ensuring external services can connect via network proxy while local devices can remain unaffected. This update addresses key customer requests and lays the foundation for future cloud-based functionality.Extended visitor durationUntil now visitors in Access Commander were limited to a maximum visit of 30 days. From Access Commander 3.4 we are increasing this duration to a maximum of 90 days allowing temporary access that can span months. Ideal for customers integrating Access Commander with third-party systems that need support for longer visits.Device typesWe've added a new column to the device list page called 'Types'. It's now even easier to see which device is an intercom, Access Unit, answering unit or electronic lock. The list can be filtered based on the selected type.New DevicesThis release supports the new 2N IP Force 2.0 intercom the 2N Clip 2wire-IP answering unit, and of course, 2N Fortis electronic locks.Additional NotesIMPORTANT - For security reasons, this version of Access Commander is not compatible with 2N Intercoms and 2N Access Units running firmware version 2.37 or older. Access Commander will not manage devices with these firmware versions even if compatibility mode is enabled. Please ensure all devices are running firmware version 2.38 or newer before upgrading.Required Device Firmware Versions for Full Feature Support
Minimum Supported Firmware Versions (Devices running firmware older than these versions will not sync with Access Commander)
API Changes
|
|||||||||
Firmware
| Nazwa pliku | Kategoria | Typ |
|---|
Najnowsze podręczniki
Inne dokumenty
| Nazwa pliku | Kategoria | Typ | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Software 3.6.1 - 2N Access Commander (VirtualBox, VMware) | Oprogramowanie i oprogramowanie sprzętowe | Oprogramowanie | |||||||
2N Access Commander version 3.6.1 (May 2026)2N Access Commander version 3.6 introduces a faster way to configure devices through device templates, a centralised call log for intercoms, a dedicated Company Admin role for managing organisation-level settings, and several quality-of-life improvements throughout the system. Bugs fixed in 3.6.1:Addresses a critical bug that a ects a small number of Access Commander Box installations and My2N app pairing. New Features:Device TemplatesAdmins can now save and edit the configuration file of any 2N OS–based device and apply it to other devices individually or in bulk.
Important:
Call logsCall logs provide administrators with a single, unified view of incoming and outgoing calls from all intercoms and elevator communication devices.
Please note: If both the caller and receiver are managed by Access Commander, the system Company admin roleThe new Company Admin role gives designated users control over company-specific settings that previously required full administrator rights. This role can be combined with others such as User Manager or Visitor Manager, depending on requirements. Company Admin rights include:
Other improvements:Pairing with the My2N mobile app is now faster and more secure. Users can pair the app via a QR code displayed in Access Commander or from a link or QR code sent by email. (Supported on devices running FW 2.50/3.0 and higher).
Required Device Firmware Versions for Full Feature Support
Note - some older 2N devices cannot support versions higher than 2.50. Minimum Supported Firmware Versions (Devices running firmware older than these versions will not sync with Access Commander)
|
|||||||||
| Software 3.6.1 - 2N Access Commander (Hyper-V) | Oprogramowanie i oprogramowanie sprzętowe | Oprogramowanie | |||||||
2N Access Commander version 3.6.1 (May 2026)2N Access Commander version 3.6 introduces a faster way to configure devices through device templates, a centralised call log for intercoms, a dedicated Company Admin role for managing organisation-level settings, and several quality-of-life improvements throughout the system. Bugs fixed in 3.6.1:Addresses a critical bug that a ects a small number of Access Commander Box installations and My2N app pairing. New Features:Device TemplatesAdmins can now save and edit the configuration file of any 2N OS–based device and apply it to other devices individually or in bulk.
Important:
Call logsCall logs provide administrators with a single, unified view of incoming and outgoing calls from all intercoms and elevator communication devices.
Please note: If both the caller and receiver are managed by Access Commander, the system Company admin roleThe new Company Admin role gives designated users control over company-specific settings that previously required full administrator rights. This role can be combined with others such as User Manager or Visitor Manager, depending on requirements. Company Admin rights include:
Other improvements:Pairing with the My2N mobile app is now faster and more secure. Users can pair the app via a QR code displayed in Access Commander or from a link or QR code sent by email. (Supported on devices running FW 2.50/3.0 and higher).
Required Device Firmware Versions for Full Feature Support
Note - some older 2N devices cannot support versions higher than 2.50. Minimum Supported Firmware Versions (Devices running firmware older than these versions will not sync with Access Commander)
|
|||||||||
| Software 3.5.2 - 2N Access Commander (VirtualBox, VMware) | Oprogramowanie i oprogramowanie sprzętowe | Oprogramowanie | |||||||
2N Access Commander version 3.5.2 (February 2026)2N Access Commander version 3.5 introduces enhanced support for 2N Fortis Locks, a new card search function, company specific time profiles, support for emergency elevator communicators and other improvements.
New Features in 3.5.0Enhanced support for 2N Fortis electronic locks
New search improvements
Company specific time profilesIn multi-company installations, admins can now assign new time profiles to companies. An access manager will only see system-wide time profiles or time profiles assigned to their company. The creation of a new time profile by an access manager will not be visible to other companies.2N Emergency Elevator Communicator supportAccess Commander now supports 2N OS based elevator devices (LiftIP 2.0 and Sentrio). The online state of these devices can be monitored from the device list, monitoring page and can be notified by email. As with all 2N OS devices, access to the device web configuration is also supported, with Access Commander remembering the device password.Other improvements:
Required Device Firmware Versions for Full Feature Support
Note - some older 2N devices cannot support versions higher than 2.50.x Minimum Supported Firmware Versions (Devices running firmware older than these versions will not sync with Access Commander)
API Changes
|
|||||||||
| Software 3.5.2 - 2N Access Commander (Hyper-V) | Oprogramowanie i oprogramowanie sprzętowe | Oprogramowanie | |||||||
2N Access Commander version 3.5.2 (February 2026)2N Access Commander version 3.5 introduces enhanced support for 2N Fortis Locks, a new card search function, company specific time profiles, support for emergency elevator communicators and other improvements.
New Features in 3.5.0Enhanced support for 2N Fortis electronic locks
New search improvements
Company specific time profilesIn multi-company installations, admins can now assign new time profiles to companies. An access manager will only see system-wide time profiles or time profiles assigned to their company. The creation of a new time profile by an access manager will not be visible to other companies.2N Emergency Elevator Communicator supportAccess Commander now supports 2N OS based elevator devices (LiftIP 2.0 and Sentrio). The online state of these devices can be monitored from the device list, monitoring page and can be notified by email. As with all 2N OS devices, access to the device web configuration is also supported, with Access Commander remembering the device password.Other improvements:
Required Device Firmware Versions for Full Feature Support
Note - some older 2N devices cannot support versions higher than 2.50.x Minimum Supported Firmware Versions (Devices running firmware older than these versions will not sync with Access Commander)
API Changes
|
|||||||||
| Fortis Commander | Oprogramowanie i oprogramowanie sprzętowe | Oprogramowanie | |||||||
|
|||||||||
| Zdjęcia – 2N Fortis Locks | Marketing | Photos |
Pobierać
|
||||||
|
|||||||||
| Zdjęcia – 2N Fortis Handle | Marketing | Photos |
Pobierać
|
||||||
|
|||||||||
| Software 3.4.2 - 2N Access Commander (VirtualBox, VMware) | Oprogramowanie i oprogramowanie sprzętowe | Oprogramowanie | |||||||
2N® Access Commander version 3.4.2 (September 2025)2N® Access Commander version 3.4 introduced a range of new features, detailed below. This subsequent 3.4.2 release adds support for 2N OS firmware 2.49, delivers minor text improvements, and resolves a few small issues.This release includes security fixes and addresses concerns regarding the following user reported vulnerabilities.
It is strongly recommended that all users upgrade to version 3.4.2 to ensure the security of their installation. As with all Access Commander upgrades, this release updates external dependencies critical for security. IMPORTANT - Due to a redesign of the proxy server settings, upgrading to this version from 3.3.1 or lower will erase any existing configuration—administrators will need to re-enter the proxy details after the update. New Features & Improvements:2N Fortis electronic locksThis release supports 2N Fortis wireless electronic locks (handles and cylinders) in offline mode. Locks can be added to Access Commander and assigned to zones, similar to other access readers in the software. 2N Fortis locks adhere to the OSS Secure ID standard, where access rights are stored and encrypted on the card or fob (DESFire EV3) rather than the device itself. Due to the offline nature of these devices, active monitoring or control is not supported. In this version of Access Commander, a 2N intercom or 2N Access Unit is required for writing access rights to cards and must be part of the installation.Proxy exceptions2N Access Commander now supports more granular proxy configuration, allowing administrators to define proxy server exceptions (domains or addresses). This improvement simplifies network management in complex environments, ensuring external services can connect via network proxy while local devices can remain unaffected. This update addresses key customer requests and lays the foundation for future cloud-based functionality.Extended visitor durationUntil now visitors in Access Commander were limited to a maximum visit of 30 days. From Access Commander 3.4 we are increasing this duration to a maximum of 90 days allowing temporary access that can span months. Ideal for customers integrating Access Commander with third-party systems that need support for longer visits.Device typesWe've added a new column to the device list page called 'Types'. It's now even easier to see which device is an intercom, Access Unit, answering unit or electronic lock. The list can be filtered based on the selected type.New DevicesThis release supports the new 2N IP Force 2.0 intercom the 2N Clip 2wire-IP answering unit, and of course, 2N Fortis electronic locks.Additional NotesIMPORTANT - For security reasons, this version of Access Commander is not compatible with 2N Intercoms and 2N Access Units running firmware version 2.37 or older. Access Commander will not manage devices with these firmware versions even if compatibility mode is enabled. Please ensure all devices are running firmware version 2.38 or newer before upgrading.Required Device Firmware Versions for Full Feature Support
Minimum Supported Firmware Versions (Devices running firmware older than these versions will not sync with Access Commander)
API Changes
|
|||||||||
| Software 3.4.2 - 2N Access Commander (Hyper-V) | Oprogramowanie i oprogramowanie sprzętowe | Oprogramowanie | |||||||
2N® Access Commander version 3.4.2 (September 2025)2N® Access Commander version 3.4 introduced a range of new features, detailed below. This subsequent 3.4.2 release adds support for 2N OS firmware 2.49, delivers minor text improvements, and resolves a few small issues.This release includes security fixes and addresses concerns regarding the following user reported vulnerabilities.
It is strongly recommended that all users upgrade to version 3.4.2 to ensure the security of their installation. As with all Access Commander upgrades, this release updates external dependencies critical for security. IMPORTANT - Due to a redesign of the proxy server settings, upgrading to this version from 3.3.1 or lower will erase any existing configuration—administrators will need to re-enter the proxy details after the update. New Features & Improvements:2N Fortis electronic locksThis release supports 2N Fortis wireless electronic locks (handles and cylinders) in offline mode. Locks can be added to Access Commander and assigned to zones, similar to other access readers in the software. 2N Fortis locks adhere to the OSS Secure ID standard, where access rights are stored and encrypted on the card or fob (DESFire EV3) rather than the device itself. Due to the offline nature of these devices, active monitoring or control is not supported. In this version of Access Commander, a 2N intercom or 2N Access Unit is required for writing access rights to cards and must be part of the installation.Proxy exceptions2N Access Commander now supports more granular proxy configuration, allowing administrators to define proxy server exceptions (domains or addresses). This improvement simplifies network management in complex environments, ensuring external services can connect via network proxy while local devices can remain unaffected. This update addresses key customer requests and lays the foundation for future cloud-based functionality.Extended visitor durationUntil now visitors in Access Commander were limited to a maximum visit of 30 days. From Access Commander 3.4 we are increasing this duration to a maximum of 90 days allowing temporary access that can span months. Ideal for customers integrating Access Commander with third-party systems that need support for longer visits.Device typesWe've added a new column to the device list page called 'Types'. It's now even easier to see which device is an intercom, Access Unit, answering unit or electronic lock. The list can be filtered based on the selected type.New DevicesThis release supports the new 2N IP Force 2.0 intercom the 2N Clip 2wire-IP answering unit, and of course, 2N Fortis electronic locks.Additional NotesIMPORTANT - For security reasons, this version of Access Commander is not compatible with 2N Intercoms and 2N Access Units running firmware version 2.37 or older. Access Commander will not manage devices with these firmware versions even if compatibility mode is enabled. Please ensure all devices are running firmware version 2.38 or newer before upgrading.Required Device Firmware Versions for Full Feature Support
Minimum Supported Firmware Versions (Devices running firmware older than these versions will not sync with Access Commander)
API Changes
|
|||||||||
| Karta katalogowa (EN) - 2N Fortis Handle | Marketing | Arkusz danych | |||||||
|
|||||||||
| Deklaracja zgodności (EN) - 2N Fortis Handle | Techniczny | Deklaracja zgodności | |||||||
|
|||||||||
| Prezentacja produktu (EN) - 2N Fortis Zamki elektroniczne | Marketing | Prezentacje | |||||||
|
|||||||||
FAQ
- 2N Fortis Commander - How to continue programming your site with new programming software and Access Commander 3.5
- 2N Fortis Commander - overview and how to use it
- 2N Fortis deployment with 2N Access Commander and Fortis Commander
- 2N Fortis - mechanical assembly and disassembly
- Battery replacement
- Electronic lock groups - how to efficiently set up more 2N Fortis devices in an installation
- Factory reset - How to do factory reset for 2N Fortis devices
- One card for 2N Fortis and 2N Picard at the same time
- Sizes of Spindle and Cylinder for project
- Time profiles - managing time restricted access for 2N Fortis
Dane techniczne
-
Zasilacz
- Akumulator:
- 1x CR123A 3 V
- Cykl życia baterii:
- do 230 000 otwarć (zazwyczaj 4 lata)
-
Interfe
- NFC:
- 132,56MHz
- Bluetooth®:
- 2,4GHz BLE
- RFID:
- 13,56 MHz MIFARE® DESFire® (OSS-SO)
-
Właściwości mechaniczne
- Temperatura przechowywania:
- -40°C do 65°C
- Materiał pokrętła:
- Mosiądz niklowany (obszar anteny pokryty twardym plastikiem)
- Ocena okładki:
- Brak (tylko do użytku w pomieszczeniach)
- Temperatura pracy:
- +5°C do 55°C (wersja na zewnątrz: -25°C do 65°C)
-
Tryb pracy
- Obsługiwany tryb:
- Offline
-
Wymiary
- Okrągła róża:
- średnica 55mm
- Dźwignia w kształcie litery L:
- długość 140mm
- Wymiary wrzeciona:
- 7 mm, 8 mm, 9 mm
-
Specyfikacja drzwi
- Grubość drzwi:
- 30 mm – 110 mm
- Typ drzwi:
- Drewno, stal i aluminium
- Typ ramy:
- Wąska lub szeroka rama z rozstawem osi ponad 28 mm
Dla tego produktu nie są obecnie dostępne żadne samouczki wideo.
Chcesz z kimś porozmawiać?
Nasz zespół jest tutaj dla Ciebie! Wybierz region lub obszar zainteresowania
Czat z Technikiem
Aby skontaktować się z naszym technikiem, skorzystaj z czatu na dole tej strony. Bez botów: porozmawiaj z prawdziwym technikem 2N za pomocą naszego czatu na żywo
Dostępne od 9:00 do 16:00 CET
Zadzwoń
Dostępne od 9:00 do 17:00. CET (poni-pi).
- Ogólne (czeski i angielski) +420 228 880 382
- Zjednoczone Królestwo +44 203 510 5770
- Francja +33 1 88 89 02 98
- Niemcy +44 203 510 5770
- Hiszpania +34 919 540 607
- Włochy +39 02 3055 9053
Formularz kontaktowy
Wypełnij nasz formularz pomocy technicznej, a ktoś skontaktuje się z Tobą jak najszybciej
Portal wsparcia dla dystrybutorów 2N i CIP
Twórz przypadki techniczne i zarządzaj nimi.
Wsparcie telefoniczne
Przygotuj PIN i zadzwoń do nas:
- Czechy +420 228 880 384*
- Angielski +420 228 880 574*