2N Lift8

Modular elevator system for emergency communication

This product is not sold through the Axis distribution network, please contact our representative by completing the form.

Contact Our Specialists

  • Easy installation
  • Comprehensive, modular, expandable
  • Wide range of communication interfaces
Next (8)

Features & benefits

  • White logo on black background for TÜV SÜD CERTIFIED product testing and certification.

Easy installation

Take advantage of the 2 wire communication bus for installation in the shaft. This makes for the quick and easy replacement of legacy solutions.

Comprehensive, modular, expandable

You can connect up to 8 independent lift shafts to one central 2N Lift8 unit. Each shaft can have up to 6 communication units.

Wide range of communication interfaces

Choose from a wide range of communication interfaces, among PSTN/GSM/UMTS/IP/LTE/VoLTE. The communication interface can be changed on a modular basis, without having to replace the whole system.

Simple configuration

The configuration can be done locally with the supplied configuration software application or remotely using the voice menu, software application or SMS.

Conference calls

Within each of the shafts you can run a conference call between all the connected units, including the unit in the machine room.

Fireman communication unit

The fireman unit serves during fire-fighter intervention. It activates a call with top priority, and allows you to establish a connection with the cabin communicator and machine room in the same lift shaft.

4 versions of cabin units

You can choose from the basic unit behind a panel, a cabled panel unit and units to install on the surface (‘Compact’ case) or flush mounted.

Extending modules

The system can be extended by additional I/O modules, a camera module, or an RS232 module. In addition to audio units you can remotely monitor the status of the lift controller.

Up to 6 numbers for alarm calls

2N Lift8 allows you to specify up to 6 numbers for alarm calls, their calling sequence is based on user settings.

Own call centre

The 2N Lift8 system comes with its own application for surveillance and a call centre. You obtain a comprehensive solution including supervisory software.

About 2N Lift8

A highly modular elevator communication system, where the two-wire bus makes the 2N Lift8 readily installable in any elevator context. This means that when it comes to providing for emergency elevator communications you won’t have to trouble with putting in new cabling. 2N Lift8 meets all the applicable EU standards.

Modules

Technical specifications

/
  • Power Supply (Max.):
    100-240V, 50/60Hz, 0,75A, 60W
    Backup Power Supply:
    Internal Lead Acid Battery (1,3 Ah / 3 Ah)
    Maximum Distance Between Splitters:
    100m with cable cross-section 2.5 mm²
    Connection Options:
    5 reporting units +7 splitters + 8 I/O modules
    Interface For Connection With Lift Service Centre:
    Choice of PSTN/GSM/UMTS/LTE/VoIP
    Configuration And Monitoring:
    Voice menu / USB / remote
    Indicators:
    5× LED, three-colour
    Dimensions:
    300×170×72mm
    Weight:
    2,7 kg
    Operating Temperature:
    0 to 40°C
  • Bands:
    1900MHz, LTE Module - EG25-G, LTE-FDD: B1/B2/B3/B4/B5/B7/B8/B12/B13/B18/B19/B20/B25/B26/B28, LTE-TDD: B38/B39/B40/B41
    SIM Card:
    mini, 3V, plug-in
    Antenna:
    one external with SMA connector
  • Power Supply:
    18V, 200mA
    Camera Interface:
    RS232/RS485 and RJ-45
    Dimensions:
    142 × 98 × 34 mm
    Memory Card:
    microSD up to 32GB
  • Power Supply:
    24V, from Central Unit or local
    Capacity:
    7 audio units and Camera module
    Max. Overall Length:
    600 m
    Lift Block Impulse:
    Relay, both NO and NC contacts
    Dimensions:
    142 × 98 × 34 mm
  • Cover:
    robust aluminum casting
    Operating Temperature:
    -25 to 55°C
    Operating Relative Humidity:
    (non-condensing) 10 - 95%
    Storage Temperature:
    -40 to 70 °C
    Dimensions:
    217 × 109 × 83 mm, (242 × 136 × 83 mm including the frame)
    Weight:
    netto 2kg, brutto 2,5kg
    IP Coverage:
    IP69K
  • Flush mount box dimensions:
    238 × 108 × 45 mm
    Stainless steel faceplate with button:
    256 × 126 mm
  • Power supply:
    24V, from Central Unit or local
    Capacity:
    4 inputs, 4 outputs
    Inputs:
    galvanized insulation, 12 – 24V DC, AC, DC
    Outputs:
    relay, NC/NO contacts, max. 250V, 5A
Three women and two men discussing business around an open laptop in an office

Register for Technical Training

View our technical training courses. Choose the one that suits you best.

See more

Resources & downloads

Accessories

Example of a typical connection - Emergency communication

2N Lift 8 scheme of connection for ip access control

Example of a typical connection - Evacuation communication

A technical flow chart diagram illustrating the connection scheme for a LIFT8 elevator emergency communication system.

Complementary Products

Back to top