Product Support 2N Access Unit M
Slim access control reader
Apps & Software
| File Name | Category | Type | |||||||
|---|---|---|---|---|---|---|---|---|---|
| 2N USB Driver 1.9.0 | Software and Firmware | Software, Driver | |||||||
2N USB Driver version 1.9.0 (April 2026)This driver allows:- Enrolling of RFID cards from 9137421E External RFID Reader 125kHz + 13.56MHz (USB interface), or the HID SEOS compatible version 9137424E, directly to web interface of 2N IP Intercoms, 2N Access Units and 2N Access Commander.- Enrolling of users into Bluetooth access control. Users need to have the 2N My2N app on their smartphone and Bluetooth capable 2N devices. - Enrolling of users for access control using the 9137423E USB Fingerprint reader. - Certificate valid until December 2026. Compatible cards:- Low-Frequency Cards (125 kHz)- High-Frequency Cards (13.56 MHz, ISO/IEC 14443A) - 2N PICard (MIFARE® DESFire® EV2 / EV3) - 2N Secure Cards with Fortis Lock Support (MIFARE® DESFire® EV2 / EV3) - HID® Secure Cards (HID iCLASS SE®, HID Seos®, HID MIFARE® DESFire® EV3) PC requirements- Windows 10 or newer- With Microsoft .NET Desktop Runtime 8.0 (x86) or newer (2N USB Driver installer will download required dependencies automatically if missing) Changes in the version 1.9.0:- Support for MIFARE® DESFire® cards with third-party applications installed (Cards must support anonymous application creation)- Adds support for Access Commander version 3.6 |
|||||||||
| Software 3.0.9 - 2N Network Scanner | Software and Firmware | Software | |||||||
|
|||||||||
Firmware
| File Name | Category | Type | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Firmware 3.2.0 - 2N Access Unit M | Software and Firmware | Firmware | |||||||
2N OS version 3.2.0 for 2N IP Access Control Systems includes the following changesNew Functions and Improvements
Essential Corrections
5d7e6698ad2fdf22985b5b5015736a72f988a0383218e5e80b0d7946f67a1c19
|
|||||||||
| Firmware 3.1.0 - 2N Access Unit M | Software and Firmware | Firmware | |||||||
2N OS version 3.1.0 for 2N IP Access Control Systems includes the following changesPrecautions to be taken during update to FW version 3.1.x
Essential Corrections
360192b26d0892cbcbeed84dd0964ca65f138b3780f10f53b72d737558300a2f
|
|||||||||
| Firmware 3.0.2 - 2N Access Unit M | Software and Firmware | Firmware | |||||||
2N OS version 3.0.2 for 2N IP Access Control Systems includes the following changesImportant update notice
Essential Corrections
2N OS version 3.0.0 for 2N IP Access Control Systems includes the following changesPrecautions to be taken during update to FW version 3.0.x
Introducing the MVP of our new graphical interface
New Functions and Improvements
Essential Corrections
17f86789c6dcc918772e8b2cbc5413410a71887559b44efcedde1209c324f11e
|
|||||||||
| Firmware 2.49.1.75 - 2N Access Unit M | Software and Firmware | Firmware | |||||||
2N OS version 2.49.1 for 2N IP Access Control Systems includes the following changesEssential Corrections
2N OS version 2.49.0 for 2N IP Access Control Systems includes the following changesPrecautions to be taken during update to FW version 2.49.x
New Functions and Improvements
Essential Corrections
b4f01848a52eed80a92013d555c68047b8757f0954011b3f54458f48cb625ee2
|
|||||||||
| Firmware 2.48.1 - 2N Access Unit M | Software and Firmware | Firmware | |||||||
2N OS version 2.48.1 for 2N IP Access Control Systems includes the following changesPrecautions to be taken during update to FW version 2.48.x
New Functions and Improvements
Essential Corrections
8ea0e9b90fd94fb1ca34d8c8ec5abcbad1ca2ed8bf4866534b5b6b11b72b4937
|
|||||||||
| Firmware 2.48.0 - 2N Access Unit M - 2N Fortis support | Software and Firmware | Firmware, | |||||||
2N OS version 2.48.0 for 2N IP Access Control Systems includes the following changesPrecautions to be taken during update to FW version 2.48.x
New Functions and Improvements
Essential Corrections
66626e5b67e4c1171882b0179bb59bb460330983faf3fa075bd4ac873877e91f
|
|||||||||
Other Documents
| File Name | Category | Type | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Firmware 3.2.0 - 2N Access Unit M | Software and Firmware | Firmware | |||||||
2N OS version 3.2.0 for 2N IP Access Control Systems includes the following changesNew Functions and Improvements
Essential Corrections
5d7e6698ad2fdf22985b5b5015736a72f988a0383218e5e80b0d7946f67a1c19
|
|||||||||
| 2N USB Driver 1.9.0 | Software and Firmware | Software, Driver | |||||||
2N USB Driver version 1.9.0 (April 2026)This driver allows:- Enrolling of RFID cards from 9137421E External RFID Reader 125kHz + 13.56MHz (USB interface), or the HID SEOS compatible version 9137424E, directly to web interface of 2N IP Intercoms, 2N Access Units and 2N Access Commander.- Enrolling of users into Bluetooth access control. Users need to have the 2N My2N app on their smartphone and Bluetooth capable 2N devices. - Enrolling of users for access control using the 9137423E USB Fingerprint reader. - Certificate valid until December 2026. Compatible cards:- Low-Frequency Cards (125 kHz)- High-Frequency Cards (13.56 MHz, ISO/IEC 14443A) - 2N PICard (MIFARE® DESFire® EV2 / EV3) - 2N Secure Cards with Fortis Lock Support (MIFARE® DESFire® EV2 / EV3) - HID® Secure Cards (HID iCLASS SE®, HID Seos®, HID MIFARE® DESFire® EV3) PC requirements- Windows 10 or newer- With Microsoft .NET Desktop Runtime 8.0 (x86) or newer (2N USB Driver installer will download required dependencies automatically if missing) Changes in the version 1.9.0:- Support for MIFARE® DESFire® cards with third-party applications installed (Cards must support anonymous application creation)- Adds support for Access Commander version 3.6 |
|||||||||
| Firmware 3.1.0 - 2N Access Unit M | Software and Firmware | Firmware | |||||||
2N OS version 3.1.0 for 2N IP Access Control Systems includes the following changesPrecautions to be taken during update to FW version 3.1.x
Essential Corrections
360192b26d0892cbcbeed84dd0964ca65f138b3780f10f53b72d737558300a2f
|
|||||||||
| Declaration of usability (EN) | Technical | Declaration of usability | |||||||
|
|||||||||
| 2N Product Catalogue (US) | Marketing | Catalogue | |||||||
|
|||||||||
| Firmware 3.0.2 - 2N Access Unit M | Software and Firmware | Firmware | |||||||
2N OS version 3.0.2 for 2N IP Access Control Systems includes the following changesImportant update notice
Essential Corrections
2N OS version 3.0.0 for 2N IP Access Control Systems includes the following changesPrecautions to be taken during update to FW version 3.0.x
Introducing the MVP of our new graphical interface
New Functions and Improvements
Essential Corrections
17f86789c6dcc918772e8b2cbc5413410a71887559b44efcedde1209c324f11e
|
|||||||||
| Datasheet (EN) - 2N Access Unit M | Marketing | Datasheet | |||||||
|
|||||||||
| Firmware 2.49.1.75 - 2N Access Unit M | Software and Firmware | Firmware | |||||||
2N OS version 2.49.1 for 2N IP Access Control Systems includes the following changesEssential Corrections
2N OS version 2.49.0 for 2N IP Access Control Systems includes the following changesPrecautions to be taken during update to FW version 2.49.x
New Functions and Improvements
Essential Corrections
b4f01848a52eed80a92013d555c68047b8757f0954011b3f54458f48cb625ee2
|
|||||||||
| Software 3.0.9 - 2N Network Scanner | Software and Firmware | Software | |||||||
|
|||||||||
| Firmware 2.48.1 - 2N Access Unit M | Software and Firmware | Firmware | |||||||
2N OS version 2.48.1 for 2N IP Access Control Systems includes the following changesPrecautions to be taken during update to FW version 2.48.x
New Functions and Improvements
Essential Corrections
8ea0e9b90fd94fb1ca34d8c8ec5abcbad1ca2ed8bf4866534b5b6b11b72b4937
|
|||||||||
| Firmware 2.48.0 - 2N Access Unit M - 2N Fortis support | Software and Firmware | Firmware, | |||||||
2N OS version 2.48.0 for 2N IP Access Control Systems includes the following changesPrecautions to be taken during update to FW version 2.48.x
New Functions and Improvements
Essential Corrections
66626e5b67e4c1171882b0179bb59bb460330983faf3fa075bd4ac873877e91f
|
|||||||||
| RED stats description | Technical | Other | |||||||
|
|||||||||
FAQ
- 2N Fortis deployment with 2N Access Commander and Fortis Commander
- 2N Network Scanner - Locating 2N devices in the network
- Bluetooth - Encryption Keys for Location
- Certification for web authentication
- Connecting an old intercom to a 2N Access Unit using a 2N Security Relay
- External IP Relay 9137410E & 9137411E - Controlling using HTTP commands from a 2N IP intercom or 2N Access Unit
- External USB readers - Driver installation & usage
- External USB RFID reader 125kHz EMarine - Usage without any additional driver
- Factory reset on 2N Access Units
- Firmware upgrade - How to make a firmware upgrade of 2N Access Unit?
- How to backup configuration and how to capture a trace on 2N Access Unit
- How to provide all information to effectively resolve a technical issue on 2N Access Unit?
- How to provide all information to effectively resolve a technical issue with 2N OS device
- HTTP Commands – How to configure them in Answering units
- Import of users from device
- IP address - How to get IP address of 2N Access Units?
- Issues accessing the web interface on macOS
- License Plate Recognition (LPR)
- Management over the Internet
- Milestone XProtect - Alarm event from 2N device on Milestone XProtect
- My2N App Offline Pairing - Opening doors via Bluetooth
- Offline Bluetooth pairing and modes (Tap In App, Touch On Device, Card, Motion Detection)
- OpenVPN server & client
- Password recovery in 2N OS devices
- REX button connectivity
- REX button - How to connect to a 2N Access Unit
- RFID Card/RFID Tag Configuration
- Static IP address - How to set up static IP address on 2N Access Units?
- The example of OSDP module connecting and using on 2N Intercom
- Time Profiles
Technical specifications
/
-
Power Supply
- Type:
- PoE and/or 12 V/1 A DC
- PoE:
- 802.3af (Class 0–12.95 W)
-
Interfaces
- LAN:
- 10/100 BASE-TX Auto-MDIX, RJ-45 male (29m pigtail)
- Recommended Cabling:
- Cat-5e or better
- Active Switch Output:
- 8 to 12V, DC, max 600mA
- Passive Switch:
- NO/NC relay, 30V, 1A, AC, DC
- Inputs:
- 2N, OFF = open or Uin> 1.5V / ON = short-circuit or Uin< 1.5V
- Tamper Switch:
- inbuilt
- Audio:
- buzzer, 1W, 8Ω
- Supported Protocols:
- DHCP opt. 66, SMTP, TFTP, HTTP, HTTPS, Syslog
-
Bluetooth Reader
- Version:
- compatible with Bluetooth 5.0 LE
- Range:
- adjustable short - typically up to 3m, long - typically up to 10m, distances should serve only as an approximate guide and may vary depending on the phone model and installation environment
- Security:
- 128encryption
- RX Sensitivity:
- 94.8dB
- Mode:
- card, touch, tap in app
-
RFID Card Reader
- Supported Frequencies:
- 125kHz, 13.56MHz
- 125 KHz:
- EM4xxx
- 13.56 MHz:
- reads UID (CSN) ISO14443A, PicoPass (HID iClass), FeliCa, ST SR(IX), NFC (My2N app), Secured MIFARE DESFire EV2/EV3 cards using 2N PICard technology
-
Touch Keypad
- Technology:
- capacitive touch technology, high touch layer sensitivity (0.1pF)
- Reliability:
- regular automatic calibration (SmartSence Auto-tunning), does not detect false touches on wet surface
- Signalling:
- configurable backlight intensity, indication using multicoloured LEDs, acoustic response for every keypad touch
-
Mechanical Properties
- Frame:
- tempered glass with rugged plastic
- Operating Temperature:
- -40 to 60°C
- Storage Temperature:
- -40 to 60°C
- Operating Relative Humidity:
- 10%-95% (non-condensing)
- Weight:
- 500g
- Cover Rating:
- IK7, IP54
-
Dimensions
- 2N Access Unit M:
- 50 x 133 x 27 mm
- Surface mount box:
- 27 x 134 x 52 mm
-
General
- Mobile Application Support:
- Android 12, iOS 18.0 (iPhone, iPad), visionOS 2.0 (Apple Vision), watchOS 11.2 (Apple Watch) - and higher
Need to talk to someone?
Our team are here for you! Select your region or focus
Call Us
- Access Control 1-800-444-2947
- Elevators +420 228 880 382
- (English) Available from 9:00 a.m. to 5:00 p.m. CET (Mon-Fri).
Contact Form
Access control
Sign in with your Axis online account and create new ticket.
Elevators
Please complete our technical support form, and a member of the 2N team will contact you as soon as possible.