Product Support 2N Lift1
Emergency elevator communicator for an attractive price
Apps & Software
| File Name | Category | Type | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Software - ServiceTool 2.3.0.0.3 - 2N Lift1 | Software and Firmware | Software | |||||||
|
|||||||||
| SBOM - 2N Lift1 | Software and Firmware | Software | |||||||
|
|||||||||
Firmware
Latest Manuals
Other Documents
| File Name | Category | Type | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Product Leaflet (EN) - 2N Lift1 | Marketing | Leaflets | |||||||
|
|||||||||
| Elevator systems – Catalogue HQ (EN) | Marketing | Catalogue | |||||||
|
|||||||||
| Cybersecurity in elevators (EN) | Marketing | Leaflets | |||||||
|
|||||||||
| Voice menu | Software and Firmware | Other | |||||||
|
|||||||||
| Firmware 2.1.0.0.1 - 2N Lift1 | Software and Firmware | Firmware | |||||||
|
|||||||||
| Software - ServiceTool 2.3.0.0.3 - 2N Lift1 | Software and Firmware | Software | |||||||
|
|||||||||
| Protocol Description (EN) 2N Lift M2M DTMF | Other | ||||||||
|
|||||||||
| Manual (EN) - 2N Lift1 Programming Tool | Technical | Manual | |||||||
|
|||||||||
| Description of P100 protocol implemented in 2N Lift1 and 2N Lift8 (EN) | Technical | Other | |||||||
|
|||||||||
| TÜV SÜD Czech Certificate (EN) - 2N Lift1 | Technical | Product Certification | |||||||
|
|||||||||
| Product Presentation (EN) - 2N Elevator emergency communication | Marketing | Presentations | |||||||
|
|||||||||
| SBOM - 2N Lift1 | Software and Firmware | Software | |||||||
|
|||||||||
FAQ
- 2N Lift1 - Configuration backup - How to backup configuration, how to capture it and trace it
- 2N SingleTalk - Difference between basic and full version - What is the difference between basic and full version of 2N SingleTalk?
- 2N SingleTalk - Wont hang up automatically - What to do, if it wont hang up automatically?
- Configurating 2N Lift1 via SMS in combination with 2N EasyGate Pro
- confirmation-mode-how-to-configure-confirmation-mode-on-2n-lift1
- Connection options - What are the possibilities of connection of 2N SingleTalk?
- extending-cancel-input-how-to-use-cancel-input
- Extending switch - How many switches could be connected to 2N SingleTalk?
- External LEDs - How to connect/disconnect external LED diods of 2N Lift1 car unit
- Factory reset - How to make a factory reset on 2N Lift1
- Firmware upgrade - How to make a firmware upgrade on 2N Lift1
- Functionality-of-the-P100-Protocol-in-2N-Lift-Products
- Grounding-How-to-ground-2N-SingleTalk
- Hardware versions - Difference between 2N Lift1 HW version 1 and 2N Lift1 HW version 2
- phone-line-compatibility-2n-lift1-2n-lift8-a-2n-lift-ip
- Providing technical information to effectively resolve a technical issue on 2N Lift1
- RMA - What to check before the RMA process for 2N analog Intercoms
- RMA - What to check before the RMA process for 2N Lift1
- Troubleshooting - How to troubleshoot an issue on 2N Lift products (ST)
- user-message-how-to-record-and-upload-user-message-to-2n-lift1-communicator
Technical specifications
/
-
Electrical parameters
- Minimum line current:
- 15mA, off the hook
- Minimum line voltage:
- 22V, on the hook
- DC voltage drop in the off the hook state:
- < 9V, I = 20mA, < 12V, I = 50mA
- Resistance on the hook:
- 1MΩ >, U = 25..100V
- Impedance off the hook:
- 220Ω + 820Ω paral. 115nF, 15 to 60mA
- Attenuation:
- > 14dB, 15 to 60mA
- Bandwidth:
- 300 to 3500Hz, 15 to 60mA
- Impedance while ringing:
- > 2kΩC = 0.47µF, 25 to 50Hz
- Ringtone detection sensitivity:
- 10 to 20V, 25 to 50Hz
- Pulse dialling:
- 40 / 60ms
- Tone-dial levels:
- -9.0 +2.0/-2.5dB and -11.0dB +2.5/-2.0dB, 15 to 60mA
- Power surge protection – differential between A, B leads:
- 1000V (8 / 20µs)
- Note:
- Any ringing sequence is acceptable.
-
Switch parameters
- Minimum voltage:
- 9V AC or DC
- Maximum voltage:
- 24V AC or DC
- Maximum current:
- 1A AC or DC
- Resistance – open:
- min 400kΩ
- Resistance – closed:
- approx. 0.5Ω
- Fuse:
- resettable
-
Connection of external indicator elements
- Power supply voltage:
- 12-24V DC, external source
- Maximum switching current:
- 200mA
-
Other Parameters
- Dimensions of the Universal implementation:
- 65×130×24mm
- Dimensions of the Kompakt implementation:
- 100×185×16mm
- Operating temperature range:
- -20 – 70°C
Need to talk to someone?
Our team are here for you! Select your region or focus
Call Us
- Access Control 1-800-444-2947
- Elevators +420 228 880 382
- (English) Available from 9:00 a.m. to 5:00 p.m. CET (Mon-Fri).
Contact Form
Access control
Sign in with your Axis online account and create new ticket.
Elevators
Please complete our technical support form, and a member of the 2N team will contact you as soon as possible.