One click unlocking and hanging up mode

The steps in this article require using the web interface of a 2N device. Please follow this manual in case this is your first time using the web interface.

In case it is needed to use a 2N Indoor Touch 1.0 or 2.0 for opening the lock without picking up the call or just hang up immediately after opening it is possible to set up this feature with Automation.

Requirements

  • 2N Indoor Touch 1.0 or 2.0 with firmware version 3.5.2 / 4.3.2 or higher

  • Enhanced integration license (Part No. 9137907) or Gold license (Part No. 9137909)

  • Suitable 2N IP Intercom with firmware version 2.31 or higher

Navigate to menu Services > Automation and select one of the functions. Then create this Automation and select the correct Output that you will be controlling from the 2N Indoor Touch 1.0 or 2.0:

Automation for hanging up and unlocking in one click

Make sure that the electric opener/lock is always connected to the intercom's 12V output using a security relay to make the installation safe. The motherboard relay is used for switching lights or other peripherals that do not have to be secured.

It is always recommended that the 2N Security Relay (Part No. 9159010) is used for increased security.

 

Date of release: 11. 7. 2024

Used devices in the manual:

  • 2N IP Verso

  • 2N Indoor Touch 2.0

List of compatible hardware:

  • 2N IP Verso

  • 2N IP Vario

  • 2N IP Force

  • 2N IP Safety

  • 2N IP Base

  • 2N IP Solo

  • 2N Indoor Touch 1.0

  • 2N Indoor Touch 2.0

Czy ta strona była pomocna?