Induction Loop for Lifts
Emergency lift communication for the hearing-impaired. The Induction Loop for Lifts is an inductive loop that delivers audio to the lift-cabin interior, where it transmits the sound to hearing aids with a built-in inductive sensor. The induction loop is an indispensable assistant in resolving emergency communications from inside the lift for hearing aid users.
- Connect to any lift communicator
- Take advantage of two independent audio inputs
- Cover the lift space with a signal for the hearing-impaired
- About
- Technical area
- Accessories
- SW Applications
- Sales Area
About
Features & Benefits
-
Connect to any lift communicatorDon’t replace your lift communicator. All you need to do is to fit the induction loop where required.
-
Take advantage of two independent audio inputsConnect up to two independent audio sources. Use the induction loop not only for emergency calls but also for a floor announcer.
-
Cover the lift space with a signal for the hearing-impairedThe induction loop is fitted with an external antenna, which gives the hearing-aid signal full cabin coverage.
-
Adjustable volumeAdjust the volume of the output signal to the induction loop independently for both audio sources.
-
Standby modeDuring audio signal inactivity, you will appreciate the device switching to a low-power standby mode.
-
Two separate audio inputsConnect up to two independent signal sources, which you can transmit using the induction loop to the hearing aid.
-
External antennaThe induction loop is fitted with an external antenna, which is designed to be fitted on the lift cabin roof.
-
Arbitrary audio inputFor an existing installation any audio signal can be used as a source for the induction loop.
-
Standards and certificationsThe high quality design and compatibility with the required standards is proven by TÜV certification EN 81-28/70.
Show more
Technical Specification
Power-supply voltage | |
8-24V DC | |
Supply current for 12V power supply, load | |
Full output: | 1,1A |
Without signal: | 28mA |
Standby: | 12mA |
Transition to standby without signal | |
10s | |
Inputs | |
Galvanically separated by transformers | |
Input level for full induction | |
0.5-5 Vef, per config |
Output short-circuit resistance | |
time-unlimited | |
Frequency response | |
100Hz-5kHz ± 3dB | |
Temperature range | |
-4°F – 122°F | |
Dimensions | |
3.15 × 3.15 × 1.181 inch |
Show more
Induction Loop for Lifts Versions
2N® Lift Induction Loop Amplifier, 2 Audio Inputs
Order No.:
919622E
Complementary Products
Technical area
Documents
Technical documentation
Marketing documentation
-
Product Presentation (EN) - 2N Lift Solution
/documents/22902/191948/2N+Elevator+system+-+introduction
-
Product Leaflet (EN) - Induction Loop for Lifts
/documents/22902/219036/induction_loop_for_lifts_leaflet_a4_en_lq.pdf
Software & firmware
Case Study
Example of Typical Connection
Technical Specification
Power-supply voltage | |
8-24V DC | |
Supply current for 12V power supply, load | |
Full output: | 1,1A |
Without signal: | 28mA |
Standby: | 12mA |
Transition to standby without signal | |
10s | |
Inputs | |
Galvanically separated by transformers | |
Input level for full induction | |
0.5-5 Vef, per config |
Output short-circuit resistance | |
time-unlimited | |
Frequency response | |
100Hz-5kHz ± 3dB | |
Temperature range | |
-4°F – 122°F | |
Dimensions | |
3.15 × 3.15 × 1.181 inch |
Show more
Register for Technical Training
View our technical training courses. Choose the one that suits you best.
See more Accessories
SW Applications
Sales Area
Request information Selling Propositions
- Connect to any lift communicatorDon’t replace your lift communicator. All you need to do is to fit the induction loop where required.
- Take advantage of two independent audio inputsConnect up to two independent audio sources. Use the induction loop not only for emergency calls but also for a floor announcer.
- Cover the lift space with a signal for the hearing-impairedThe induction loop is fitted with an external antenna, which gives the hearing-aid signal full cabin coverage.
- Adjustable volumeAdjust the volume of the output signal to the induction loop independently for both audio sources.
- Standby modeDuring audio signal inactivity, you will appreciate the device switching to a low-power standby mode.
- Two separate audio inputsConnect up to two independent signal sources, which you can transmit using the induction loop to the hearing aid.
- External antennaThe induction loop is fitted with an external antenna, which is designed to be fitted on the lift cabin roof.
- Arbitrary audio inputFor an existing installation any audio signal can be used as a source for the induction loop.
- Standards and certificationsThe high quality design and compatibility with the required standards is proven by TÜV certification EN 81-28/70.
Show more
Induction Loop for Lifts Versions
Technical Specification
Power-supply voltage | |
8-24V DC | |
Supply current for 12V power supply, load | |
Full output: | 1,1A |
Without signal: | 28mA |
Standby: | 12mA |
Transition to standby without signal | |
10s | |
Inputs | |
Galvanically separated by transformers | |
Input level for full induction | |
0.5-5 Vef, per config |
Output short-circuit resistance | |
time-unlimited | |
Frequency response | |
100Hz-5kHz ± 3dB | |
Temperature range | |
-4°F – 122°F | |
Dimensions | |
3.15 × 3.15 × 1.181 inch |
Show more
Documents
Technical documentation
Marketing documentation
- Product Presentation (EN) - 2N Lift Solution /documents/22902/191948/2N+Elevator+system+-+introduction
- Product Leaflet (EN) - Induction Loop for Lifts /documents/22902/219036/induction_loop_for_lifts_leaflet_a4_en_lq.pdf
Software & firmware