2N® Lift8
A highly modular elevator communication system, where the two-wire bus makes the 2N® Lift8 readily installable in any elevator context. This means that when it comes to providing for emergency elevator communications you won’t have to trouble with putting in new cabling. 2N® Lift8 meets all the applicable EU standards.
This product is not sold through the Axis distribution network, please contact our representative by completing the form.
- Easy installation
- Comprehensive, modular, expandable
- Wide range of communication interfaces
- About
- Technical area
- Accessories
- SW Applications
- Sales Area
About
Features & Benefits
-
Easy installationTake advantage of the 2 wire communication bus for installation in the shaft. This makes for the quick and easy replacement of legacy solutions.
-
Comprehensive, modular, expandableYou can connect up to 8 independent elevator shafts to one central 2N® Lift8 unit. Each shaft can have up to 6 communication units.
-
Wide range of communication interfacesChoose from a wide range of communication interfaces, among PSTN/GSM/UMTS/IP. The communication interface can be changed on a modular basis, without having to replace the whole system.
-
Simple configurationThe configuration can be done locally with the supplied configuration software application or remotely using the voice menu, software application or SMS.
-
Conference callsWithin each of the shafts you can run a conference call between all the connected units, including the unit in the machine room.
-
Fireman communication unitThe fireman unit serves during fire-fighter intervention. It activates a call with top priority, and allows you to establish a connection with the cabin communicator and machine room in the same elevator shaft.
-
4 versions of cabin unitsYou can choose from the basic unit behind a panel, a cabled panel unit and units to install on the surface (‘Compact’ case) or flush mounted.
-
Extending modulesThe system can be extended by additional I/O modules, a camera module, or an RS232 module. In addition to audio units you can remotely monitor the status of the elevator controller.
-
Up to 6 numbers for alarm calls2N® Lift8 allows you to specify up to 6 numbers for alarm calls, their calling sequence is based on user settings.
-
Own call centreThe 2N® Lift8 system comes with its own application for surveillance and a call centre. You obtain a comprehensive solution including supervisory software.
Show more
Compatibility with Global Technology Partners
Get to know the wide range of technologies which are compatible with our products.
Technical parameters
Central unit | |
Power supply (max.) | 100-240V; 50/60Hz; 0,75A; 60W |
Backup power supply | Internal Lead Acid Battery (1,3 Ah / 3 Ah) |
Maximum distance between splitters | 328.084 ft |
Connection options | 7 reporting units +7 splitters + 8 I/O modules |
Interface for connection with lift service centre | Choice of PSTN/GSM/UMTS/LTE/VoIP |
Configuration and monitoring | Voice menu/USB/remote |
Indicators | 5x LED, three-colour |
Dimensions and weight | 11.811 × 6.693 × 2.835 inch, 5.95 lb |
Operating temperature | 0 - 104°F |
Cellular network | |
Bands | GSM 850/900/1800/1900 MHz UMTS 800/850/900/2100 MHz LTE module (EG25-G): LTE-FDD: B1/B2/B3/B4/B5/B7/B8/B12/ B13/B18/B19/B20/B25/B26/B28 LTE-TDD: B38/B39/B40/B41 WCDMA: B1/B2/B4/B5/B6/B8/B19 GSM: B2/B3/B5/B8 |
SIM card | mini, plug-in 3V |
Antenna | one external with SMA connector |
Camera module | |
Power supply | 12 – 18V DC, max. 0,2A |
Camera Interface | RS232/RS485 and RJ-45 |
Dimensions | 5,590 × 3,858 × 1,338 inch |
Memory card | microSD up to 32GB |
Splitter | |
Power supply | 24V from Central Unit or local |
Capacity | 7 audio units and Camera module |
Max. overall length | 1968.504 ft |
Lift block impulse | Relay, both NO and NC contacts |
Dimensions | 5.591 × 3.858 × 1.339 inch |
Fireman unit & audio unit shaft (antivandal) | |
Cover | robust aluminum casting |
Operating temperature | −77°F - 131°F |
Operating relative humidity | 10% - 95% (non-condensing) |
Storage temperature | −104°F - 158°F |
Dimensions | 8,543 × 4,291 × 3,267 inch, (9,527 × 5,354 × 3,267 inch including the frame) |
Weight | netto: max. 4,409 lb, brutto: max 5,511 lb |
IP coverage | IP65 |
I/O module | |
Power supply | 24V from central unit or local |
Capacity | 4 inputs + 4 outputs |
Inputs | Galvanized insulation, 12 - 24V AC or DC |
Outputs | Relay, NO contacts, max. 250V, 5A |
Dimensions | 5.591 × 3.858 × 1.339 inch |
Show more
Typical Usage
Technical area
FAQ
Are you still looking for more information? Check out the frequently asked questions and answers.
See more Compatibility with Global Technology Partners
Get to know the wide range of technologies which are compatible with our products.
Technical parameters
Central unit | |
Power supply (max.) | 100-240V; 50/60Hz; 0,75A; 60W |
Backup power supply | Internal Lead Acid Battery (1,3 Ah / 3 Ah) |
Maximum distance between splitters | 328.084 ft |
Connection options | 7 reporting units +7 splitters + 8 I/O modules |
Interface for connection with lift service centre | Choice of PSTN/GSM/UMTS/LTE/VoIP |
Configuration and monitoring | Voice menu/USB/remote |
Indicators | 5x LED, three-colour |
Dimensions and weight | 11.811 × 6.693 × 2.835 inch, 5.95 lb |
Operating temperature | 0 - 104°F |
Cellular network | |
Bands | GSM 850/900/1800/1900 MHz UMTS 800/850/900/2100 MHz LTE module (EG25-G): LTE-FDD: B1/B2/B3/B4/B5/B7/B8/B12/ B13/B18/B19/B20/B25/B26/B28 LTE-TDD: B38/B39/B40/B41 WCDMA: B1/B2/B4/B5/B6/B8/B19 GSM: B2/B3/B5/B8 |
SIM card | mini, plug-in 3V |
Antenna | one external with SMA connector |
Camera module | |
Power supply | 12 – 18V DC, max. 0,2A |
Camera Interface | RS232/RS485 and RJ-45 |
Dimensions | 5,590 × 3,858 × 1,338 inch |
Memory card | microSD up to 32GB |
Splitter | |
Power supply | 24V from Central Unit or local |
Capacity | 7 audio units and Camera module |
Max. overall length | 1968.504 ft |
Lift block impulse | Relay, both NO and NC contacts |
Dimensions | 5.591 × 3.858 × 1.339 inch |
Fireman unit & audio unit shaft (antivandal) | |
Cover | robust aluminum casting |
Operating temperature | −77°F - 131°F |
Operating relative humidity | 10% - 95% (non-condensing) |
Storage temperature | −104°F - 158°F |
Dimensions | 8,543 × 4,291 × 3,267 inch, (9,527 × 5,354 × 3,267 inch including the frame) |
Weight | netto: max. 4,409 lb, brutto: max 5,511 lb |
IP coverage | IP65 |
I/O module | |
Power supply | 24V from central unit or local |
Capacity | 4 inputs + 4 outputs |
Inputs | Galvanized insulation, 12 - 24V AC or DC |
Outputs | Relay, NO contacts, max. 250V, 5A |
Dimensions | 5.591 × 3.858 × 1.339 inch |
Show more
Register for Technical Training
View our technical training courses. Choose the one that suits you best.
See more Sales Area
Request information Selling Propositions
- Easy installationTake advantage of the 2 wire communication bus for installation in the shaft. This makes for the quick and easy replacement of legacy solutions.
- Comprehensive, modular, expandableYou can connect up to 8 independent elevator shafts to one central 2N® Lift8 unit. Each shaft can have up to 6 communication units.
- Wide range of communication interfacesChoose from a wide range of communication interfaces, among PSTN/GSM/UMTS/IP. The communication interface can be changed on a modular basis, without having to replace the whole system.
- Simple configurationThe configuration can be done locally with the supplied configuration software application or remotely using the voice menu, software application or SMS.
- Conference callsWithin each of the shafts you can run a conference call between all the connected units, including the unit in the machine room.
- Fireman communication unitThe fireman unit serves during fire-fighter intervention. It activates a call with top priority, and allows you to establish a connection with the cabin communicator and machine room in the same elevator shaft.
- 4 versions of cabin unitsYou can choose from the basic unit behind a panel, a cabled panel unit and units to install on the surface (‘Compact’ case) or flush mounted.
- Extending modulesThe system can be extended by additional I/O modules, a camera module, or an RS232 module. In addition to audio units you can remotely monitor the status of the elevator controller.
- Up to 6 numbers for alarm calls2N® Lift8 allows you to specify up to 6 numbers for alarm calls, their calling sequence is based on user settings.
- Own call centreThe 2N® Lift8 system comes with its own application for surveillance and a call centre. You obtain a comprehensive solution including supervisory software.
Show more
Compatibility with Global Technology Partners
Get to know the wide range of technologies which are compatible with our products.
Related Norms and Certificates
The quality of our products is crucial to us and our customers, which is why they fully comply with strict European Union standards.
Technical parameters
Central unit | |
Power supply (max.) | 100-240V; 50/60Hz; 0,75A; 60W |
Backup power supply | Internal Lead Acid Battery (1,3 Ah / 3 Ah) |
Maximum distance between splitters | 328.084 ft |
Connection options | 7 reporting units +7 splitters + 8 I/O modules |
Interface for connection with lift service centre | Choice of PSTN/GSM/UMTS/LTE/VoIP |
Configuration and monitoring | Voice menu/USB/remote |
Indicators | 5x LED, three-colour |
Dimensions and weight | 11.811 × 6.693 × 2.835 inch, 5.95 lb |
Operating temperature | 0 - 104°F |
Cellular network | |
Bands | GSM 850/900/1800/1900 MHz UMTS 800/850/900/2100 MHz LTE module (EG25-G): LTE-FDD: B1/B2/B3/B4/B5/B7/B8/B12/ B13/B18/B19/B20/B25/B26/B28 LTE-TDD: B38/B39/B40/B41 WCDMA: B1/B2/B4/B5/B6/B8/B19 GSM: B2/B3/B5/B8 |
SIM card | mini, plug-in 3V |
Antenna | one external with SMA connector |
Camera module | |
Power supply | 12 – 18V DC, max. 0,2A |
Camera Interface | RS232/RS485 and RJ-45 |
Dimensions | 5,590 × 3,858 × 1,338 inch |
Memory card | microSD up to 32GB |
Splitter | |
Power supply | 24V from Central Unit or local |
Capacity | 7 audio units and Camera module |
Max. overall length | 1968.504 ft |
Lift block impulse | Relay, both NO and NC contacts |
Dimensions | 5.591 × 3.858 × 1.339 inch |
Fireman unit & audio unit shaft (antivandal) | |
Cover | robust aluminum casting |
Operating temperature | −77°F - 131°F |
Operating relative humidity | 10% - 95% (non-condensing) |
Storage temperature | −104°F - 158°F |
Dimensions | 8,543 × 4,291 × 3,267 inch, (9,527 × 5,354 × 3,267 inch including the frame) |
Weight | netto: max. 4,409 lb, brutto: max 5,511 lb |
IP coverage | IP65 |
I/O module | |
Power supply | 24V from central unit or local |
Capacity | 4 inputs + 4 outputs |
Inputs | Galvanized insulation, 12 - 24V AC or DC |
Outputs | Relay, NO contacts, max. 250V, 5A |
Dimensions | 5.591 × 3.858 × 1.339 inch |
Show more